Article (Scientific journals)
Balancing Acute and Chronic Occupational Risks: The Use of Nitrile Butadiene Rubber Undergloves by Firefighters to Reduce Exposure to Toxic Contaminants.
Everaert, Stijn; Schoeters, Greet; Claes, Karel et al.
2023In Toxics, 11 (6), p. 534
Peer Reviewed verified by ORBi
 

Files


Full Text
toxics-11-00534.pdf
Author postprint (676.92 kB)
Download

All documents in ORBi UMONS are protected by a user license.

Send to



Details



Keywords :
burn; exposure; firefighters; nitrile butadiene rubber; risk assessment; undergloves; Toxicology; Health, Toxicology and Mutagenesis; Chemical Health and Safety
Abstract :
[en] Firefighters are exposed via multi-route exposure to a multitude of chemicals (PAHs, VOCs, flame retardants, dioxins, etc.) that may cause acute and long-term health effects. The dermal absorption of contaminants is a major contributor to the overall exposure and can be reduced by wearing appropriate personal protective equipment. As leather firefighters' gloves cannot be decontaminated regularly by wet cleaning, many Belgian firefighters wear supplementary undergloves made of nitrile butadiene rubber (NBR) to protect against the accumulation of toxicants. However, the safety of this practice has been questioned. In this commentary, the current practice and risks are outlined for the first time, assessed by an interdisciplinary working group of the Belgian Superior Health Council. As NBR sticks to the skin more at high temperatures, the contact time on removal will be prolonged, posing an additional risk for deeper burns. However, based on the physicochemical properties of NBR and the existing experience of firefighters and burn centers, it is estimated that such incidents occur relatively rarely in practice. On the other hand, the risk of repeated exposure to contaminated gloves if no undergloves are worn is unacceptable. Despite the slightly increased risk for deeper burns, it is concluded that wearing disposable NBR gloves under regular firefighters' gloves is an appropriate and effective preventive measure against toxic contamination. The nitrile butadiene rubber must always be fully covered to avoid any contact with the heat.
Disciplines :
Materials science & engineering
Author, co-author :
Everaert, Stijn ;  Chemical Environmental Factors Group, Superior Health Council, 1060 Brussels, Belgium
Schoeters, Greet ;  Department of Biomedical Sciences, University of Antwerp, 2650 Antwerp, Belgium
Claes, Karel ;  Burn Center & Department of Plastic Surgery, Ghent University Hospital, 9000 Ghent, Belgium
RAQUEZ, Jean-Marie  ;  Université de Mons - UMONS > Faculté des Science > Service des Matériaux Polymères et Composites
Buffel, Bart ;  Department of Materials Engineering, KU Leuven, 8200 Bruges, Belgium
Vanhaecke, Tamara ;  Department of In Vitro Toxicology and Dermato-Cosmetology, Vrije Universiteit Brussel, 1050 Brussels, Belgium
Moens, Jonas ;  Belgian Poison Centre, 1120 Brussels, Belgium
Laitinen, Juha ;  Pelastusopisto, Emergency Services Academy Finland, 70821 Kuopio, Finland
Van Larebeke, Nicolas ;  Department of Radiotherapy and Experimental Cancerology, Ghent University, 9000 Ghent, Belgium ; Department of Analytical, Environmental and Geo-Chemistry, Vrije Universiteit Brussel, 1050 Brussels, Belgium
Godderis, Lode ;  Center for Environment and Health, Department of Public Health and Primary Care, KU Leuven, 3000 Leuven, Belgium ; IDEWE, External Service for Prevention and Protection at Work, 3001 Heverlee, Belgium
Language :
English
Title :
Balancing Acute and Chronic Occupational Risks: The Use of Nitrile Butadiene Rubber Undergloves by Firefighters to Reduce Exposure to Toxic Contaminants.
Publication date :
15 June 2023
Journal title :
Toxics
eISSN :
2305-6304
Publisher :
MDPI, Switzerland
Volume :
11
Issue :
6
Pages :
534
Peer reviewed :
Peer Reviewed verified by ORBi
Research unit :
S816 - Matériaux Polymères et Composites
Research institute :
R400 - Institut de Recherche en Science et Ingénierie des Matériaux
Available on ORBi UMONS :
since 12 December 2023

Statistics


Number of views
23 (0 by UMONS)
Number of downloads
129 (0 by UMONS)

Scopus citations®
 
3
Scopus citations®
without self-citations
3
OpenAlex citations
 
3

Bibliography


Similar publications



Contact ORBi UMONS